Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
Int J Mol Sci ; 25(9)2024 Apr 27.
Article in English | MEDLINE | ID: mdl-38731998

ABSTRACT

Meibomian Glands (MG) are sebaceous glands responsible for the production of meibum, the main component of the Tear Film Lipid Layer (TFLL). The TFLL facilitates the spread of the tear film over the ocular surface, provides stability and reduces tear evaporation. Alterations in meibum composition lead to different ocular alterations like Meibomian Gland Dysfunction (MGD) and subsequent Evaporative Dry Eye (EDE). The aim of the present study was to investigate the composition and abundance of meibum lipids and their relationship with eyelid margin abnormalities, lipid layer patterns and MG status. The study utilizes a lipidomic approach to identify and quantify lipids in meibum samples using an Elute UHPLC system. This system considered all four dimensions (mass/charge, retention time, ion mobility and intensity) to provide the accurate identification of lipid species. Samples were categorized as healthy or low/no signs of alteration (group 1) or severe signs of alteration or EDE/MGD (group 2). The current investigation found differences in Variable Importance in Projection lipid abundance between both groups for the MGD signs studied. Changes in meibum composition occur and are related to higher scores in eyelid margin hyperaemia, eyelid margin irregularity, MG orifice plugging, MG loss and lipid layer pattern.


Subject(s)
Dry Eye Syndromes , Lipidomics , Lipids , Meibomian Gland Dysfunction , Meibomian Glands , Tears , Humans , Lipidomics/methods , Meibomian Glands/metabolism , Dry Eye Syndromes/metabolism , Tears/metabolism , Tears/chemistry , Lipids/analysis , Female , Male , Middle Aged , Meibomian Gland Dysfunction/metabolism , Adult , Aged , Lipid Metabolism
2.
Article in English | MEDLINE | ID: mdl-38712751

ABSTRACT

OBJECTIVE: This randomised clinical trial assessed the impact on symptoms, tear film dynamics and ocular surface integrity of daily disposable silicone-hydrogel contact lenses (CLs) over a month, paying special attention to lid wiper epitheliopathy (LWE) and its implications for CL discomfort. METHODS: Neophyte CL wearers (n = 44, 21.09 ± 5.00 years old) were randomly assigned to either the experimental (n = 24) or control group (n = 20). Participants assigned to the experimental group were required to wear daily disposable CLs for 1 month for at least 8 h/day and 6 days/week. All participants were healthy subjects (no history of ocular surgery or active ocular disease) with spherical refractive errors between -8.00 and +5.00 D and cylindrical power <0.75 D. At the baseline and 1-month sessions, the Dry Eye Questionnaire 5 (DEQ-5) was completed, together with the measurement of tear film osmolarity with the TearLab osmometer, tear meniscus height (TMH) and lipid layer pattern (LLP) using a slit-lamp with Tearscope Plus attached, fluorescein break-up time (FBUT), maximum blink interval (MBI), corneal staining with fluorescein under cobalt blue light and LWE with lissamine green under slit lamp and halogen white light. RESULTS: At the baseline session, LWE showed a negative correlation with DEQ-5 (r = -0.37, p = 0.02). Significant differences in FBUT and LWE (p = 0.04) and a positive correlation between LWE and DEQ-5 (r = 0.49, p = 0.007) were observed at 1 month. Intrasession analysis at 1 month showed significant differences between the experimental and control groups in DEQ-5, FBUT and LWE (all p ≤ 0.02). Intersession analysis in the experimental group showed variations in DEQ-5, FBUT and LWE (all p ≤ 0.02) but no significant variation in the control group (all p ≥ 0.11). CONCLUSION: The presence of LWE was significantly correlated with higher symptom values in the DEQ-5. Also, participants in the experimental group presented higher values of LWE after 1 month of CL wear, in comparison with the control group.

3.
J Clin Med ; 13(3)2024 Jan 23.
Article in English | MEDLINE | ID: mdl-38337353

ABSTRACT

(1) Background: Dry eye disease (DED) is a chronic ocular surface condition that requires precise diagnostic tools. The present study aimed to investigate the diagnostic potential of the absolute inter-eye difference (|OD-OS|) in tear meniscus height (TMH) for the detection of the presence of aqueous deficient dry eye (ADDE). (2) Methods: A sample of 260 participants with dry eye complaints underwent ocular surface examinations thorough diagnostic assessments based on the Tear Film and Ocular Surface Society guidelines (TFOS DEWS II). Participants were subsequently categorized as No ADDE and ADDE based on TMH. Statistical analyses to determine the optimal TMH|OD-OS| cut-off value in a randomly selected study group (200 participants) were performed, while a separate validation analysis of the cut-off value obtained in a random cross-validation group (60 participants) was also performed. (3) Results: The significant diagnostic capability of TMH|OD-OS| (area under the curve = 0.719 ± 0.036, p < 0.001) was found. The identified cut-off value of 0.033 mm demonstrated reliable specificity (77.6%) and moderate sensitivity (59.1%). Cross-validation confirmed the cut-off value's association with the TFOS DEWS II diagnostic criterion (Cramer's V = 0.354, p = 0.006). (4) Conclusions: The present study provides evidence for the diagnostic potential of TMH|OD-OS| in identifying ADDE. The identified cut-off value enhances the specificity and offers moderate sensitivity, providing an objective tool for clinical decision making.

4.
Arq. bras. oftalmol ; 87(3): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520214

ABSTRACT

ABSTRACT Purpose: The possible variability in diagnostic test results is a statistical feature of dry eye disease patients. The clinician should consider tear film variations over time since the timing of tear film measurements is important for proper diagnosis. The purpose of the present study was to analyze the inter-week variation of osmolarity measurement in healthy and dry eye disease participants. Methods: Based on the Dry Eye Workshop II (DEWS-II) diagnostic methodology report criteria, a battery of tests (Ocular Surface Disease Index [OSDI] questionnaire, breakup time, and corneal staining) was administered to rule out the presence of dry eye disease. A total of 40 qualified volunteers were recruited into two groups: with only 20 healthy and 20 dry eye disease participants. The inter-week variation of osmolarity in the two groups was measured using a TearLab osmometer in two sessions one-week apart. The differences between the results were calculated. Results: There were no significant differences in osmolarity between the two sessions for either the healthy (paired t-test; p=0.085) or dry eye disease (paired t-test; p=0.093) participants. Moreover, there was no significant correlation between the means and differences in either session on healthy (Pearson correlation: r=0.020; p=0.935) or dry eye disease (Pearson correlation: r=-0.022; p=0.928) participants. In session 1, there was a significant difference in osmolarity values between groups (unpaired t-test; p=0.001), but no difference was found in session 2 (unpaired t-test; p=0.292). Conclusions: The present study discovered no inter-week variation in the tear film osmolarity of healthy and dry eye disease participants classified based on the DEWS-II criteria.


RESUMO Objetivo: A possível variabilidade nos resultados de testes diagnósticos é uma característica estatística dos pacientes com síndrome do olho seco. O médico deve considerar as variações do filme lacrimal ao longo do tempo, pois o momento em que o filme lacrimal é medido pode ser crítico para o diagnóstico adequado. O objetivo deste estudo foi analisar a variação semanal da osmolaridade do filme lacrimal em participantes saudáveis e em outros com síndrome do olho seco. Métodos: Com base nos critérios da metodologia de diagnóstico do relatório da Dry Eye Workshop II (DEWSII), foi aplicada uma bateria de testes (questionário do índice de doença da superfície ocular [OSDI], tempo de ruptura do filme lacrimal e coloração da córnea) para descartar a presença de síndrome do olho seco. Um total de 40 voluntários qualificados foi recrutado e distribuído em dois grupos de 20 participantes saudáveis e 20 participantes com síndrome do olho seco. A variação da osmolaridade entre semanas foi medida com um osmômetro TearLab em duas sessões com uma semana de intervalo nos dois grupos. As diferenças entre os resultados foram então calculadas. Resultados: Não foram encontradas diferenças significativas na osmolaridade entre as medidas obtidas nas duas sessões, nem no grupo de participantes saudáveis (teste de t pareado; p=0,085), nem no de participantes com síndrome do olho seco (teste de t pareado; p=0,093). Não foi detectada nenhuma correlação significativa entre as médias e diferenças entre as duas sessões entre participantes saudáveis (correlação de Pearson: r=0,020, p=0,935) e aqueles com síndrome do olho seco (correlação Pearson: r=-0,022, p=0,928). Foi encontrada uma diferença significativa nos valores de osmolaridade entre os dois grupos na primeira sessão (teste de t não pareado; p=0,001), mas nenhuma diferença foi encontrada na segunda sessão (teste de t não pareado; p=0,292). Conclusões: O presente estudo não encontrou variação entre semanas consecutivas na osmolaridade do filme lacrimal em participantes saudáveis e com síndrome do olho seco, classificados com base nos critérios do DEWSII.

5.
Ocul Immunol Inflamm ; : 1-8, 2023 Dec 05.
Article in English | MEDLINE | ID: mdl-38051590

ABSTRACT

PURPOSE: Inter-eye variability is a recognized characteristic of Dry Eye Disease (DED) and has been proposed as a diagnostic indicator in clinical practice. This study aimed to assess the diagnostic potential of the absolute difference between eyes in three key diagnostic tests recommended by the Tear Film and Ocular Surface Society Dry Eye Workshop II (TFOS DEWS II) Diagnostic Methodology report: tear film osmolarity, Fluorescein Break-Up Time (FBUT), and ocular surface staining. METHODS: A total of 180 participants were included in a cross-sectional study. Before a dry eye examination, participants completed an online self-administered OSDI questionnaire. The TFOS DEWS II diagnostic criteria for DED assessment were used: along with OSDI, osmolarity, FBUT and ocular surface staining were measured in all participants in both eyes following standardized methodology. Based on signs and symptoms, participants were diagnosed as having No DED or DED. After diagnosis, the parameters were computed as the right and left eyes' absolute inter-eye difference (|OD-OS|). RESULTS: Receiver Operating Characteristics analyses for computed parameters were used based on the previous diagnosis. ROC analyses showed that Osmolarity|OD-OS| have a diagnostic capability to differentiate between No DED and DED participants with a cut-off value of 9.5 mOsm/L (AUC = 0.745 ± 0.052, p < 0.003), whereas FBUT|OD-OS| and Corneal Stainning|OD-OS| have not (AUC, both p ≥ 0.160). CONCLUSION: The present study found that the Osmolarity|OD-OS| parameter could be used as a diagnostic indicator for DED assessment, while the FBUT|OD-OS| and the Corneal Staining|OD-OS| parameters do not have this capability.

6.
Cureus ; 15(11): e48826, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38106705

ABSTRACT

Purpose To compare intraocular pressure (IOP) values at different time points, both in the total sample and according to iridocorneal angle aperture, to assess whether IOP fluctuations were constant throughout the day, and to examine correlations with other factors. Methods Over a single day, the IOP of 34 volunteers was measured at three-hour intervals from 9:00 a.m. to 6:00 p.m. To avoid any IOP value being affected by other measurements, anamnesis, slit-lamp evaluation (with iridocorneal angle measurement), and refractive status were performed after the final measurement. The differences between IOP values at different time points and IOP fluctuation at three-hour intervals were compared by ANOVA and Friedman test, respectively, both for the total group and according to iridocorneal angle aperture. For relationships, Pearson's correlation was performed for parametric variables and Spearman's correlation for nonparametric variables. Results Significant differences were observed in IOP between time points for the total sample (p < 0.001), but not for a narrow-angle group (p = 0.058). No significant differences were found in IOP fluctuations at three-hour intervals either in the total sample or according to angle aperture (all p ≥ 0.332). There was a positive correlation of IOP at different time points (all r ≥ 0.646, all p < 0.001) but no relationship with spherical equivalent, age, or sleep duration (all p ≥ 0.057). IOP at 12:00 p.m. was correlated with a 12:00 p.m. to 3:00 p.m. fluctuation (r = 0.428, p = 0.012); and IOP fluctuation between 9:00 a.m. and 12:00 p.m. was correlated with age (r = 0.485, p = 0.004). Conclusion As IOP decreases from morning until at least 6:00 p.m., measuring these two values during clinical evaluation is essential for the effective monitoring and prevention of IOP-related diseases.

7.
Expert Rev Med Devices ; 20(8): 681-690, 2023.
Article in English | MEDLINE | ID: mdl-37402231

ABSTRACT

BACKGROUND: Due to the increasing use of contact lenses (CL) and the interest in ocular and body size relationships, this study aimed to compare measurements from two biometers (contact ultrasonic EchoScan US-800 and non-contact optical Lenstar LS900) with and without CL and to explore the relationship between ocular and body biometric parameters. DESIGN AND METHODS: This cross-sectional study measured ocular biometry using two biometers along with their body height and right foot length in 50 participants. Differences between biometry data from the two devices were compared and correlations between ocular and body biometric values were analyzed. RESULTS: All parameters showed interbiometric differences (p ≤ 0.030), except crystalline lens thickness during CL wear (p = 0.159). Comparing measurements with and without CL, differences were observed in axial length (p < 0.001), vitreous length measured by optical biometer (p = 0.016), and anterior chamber depth by ultrasonic biometer (p < 0.016). Lens thickness remained unaffected (p ≥ 0.190). Body height and foot length were correlated with anterior chamber depth, vitreous length, and axial length (p ≤ 0.019, r ≥ 0.330). Most biometric parameters were correlated among them using both devices (p ≤ 0.037, r ≥ 0.296). CONCLUSIONS: These biometers are not interchangeable and CL affects measurements. Body height and foot length correlate with ocular dimensions, and most ocular biometric values correlate positively.


Subject(s)
Contact Lenses , Lens, Crystalline , Humans , Anterior Chamber/anatomy & histology , Lens, Crystalline/anatomy & histology , Cross-Sectional Studies , Axial Length, Eye/anatomy & histology , Biometry , Tomography, Optical Coherence/methods , Reproducibility of Results
9.
Int Ophthalmol ; 43(7): 2349-2362, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36692700

ABSTRACT

PURPOSE: To determine if the Meibomian Gland (MG) secretion quality is associated with symptoms of ocular discomfort, hours of Video Display Terminals (VDT) use, eyelid margin abnormalities, conjunctival hyperemia, and Meibomian Gland Loss Area (MGLA) in a sample of university students. METHODS: An online survey that included an Ocular Surface Disease Index (OSDI) questionnaire and an extra question about hours of VDT use recruited an initial sample of 183 participants. Only 120 participants that fulfilled the inclusion criteria were scheduled for a battery of ocular surface and MG specific exam. The tests include: 1) meibometry, 2) slit lamp exploration of eyelid margin abnormalities (irregularity, hyperemia and MG orifices plugging), MG secretion quality and conjunctival hyperemia, and 3) Meibography. RESULTS: Significant positive correlations between the MG secretion quality and eyelid margin hyperemia, MG orifices plugging, MGLA, nasal conjunctival hyperemia, and temporal conjunctival hyperemia (Spearman Rho; all r>0.186, p<0.042) were found. Multivariate regression found association between OSDI with hours of VDT use (B=0.316, p=0.007), and eyelid hyperemia (B=0.434, p≤ 0.001). A statistical association between MG secretion quality and eyelid margin hyperemia, MG orifices plugging, MGLA and conjunctival hyperemia (Fisher's exact; all p<0.039) were found. Multivariate regression found association between MG secretion quality with MG orifices plugging (B=0.295, p=0.004) and meibometry (B=-0.001, p=0.029). CONCLUSION: Participants with higher values in MG secretion quality have higher values in eyelid margin hyperemia, MG plugging, MGLA, and conjunctival hyperemia. No direct relationship between MG secretion quality and hours of VDT use or OSDI were found.


Subject(s)
COVID-19 , Dry Eye Syndromes , Eyelid Diseases , Hyperemia , Humans , Meibomian Glands , Hyperemia/diagnosis , Universities , Tears , Eyelid Diseases/diagnosis , Students
10.
Cont Lens Anterior Eye ; 46(3): 101800, 2023 06.
Article in English | MEDLINE | ID: mdl-36572605

ABSTRACT

PURPOSE: The present study aimed to determine the relationship of non-modifiable (rheumatoid arthritis, thyroid diseases, and arterial hypertension) and modifiable risk factors (diuretics, antidepressants, or anxiolytics tranquilizers) with the different Dry Eye Disease (DED) diagnostics in a sample adjusted by antihistamines intake. METHODS: A total of 400 participants were included in a cross-sectional study. Before a dry eye examination, participants completed an online self-administered OSDI questionnaire with six additional questions about possible DED risk factors. The Tear Film and Ocular Surface Society Dry Eye Workshop II (TFOS DEWS-II) diagnostic criteria of DED was used. Based on signs and/or symptoms, participants were divided into 4 groups: No DED, Pre-clinical DED, Predisposition to DED and DED. Since the symptom scores would have been altered by the use of antihistamines, the analysis of each outcome was adjusted for this factor, where those participants were assumed to be symptomatic. RESULTS: Multivariable logistic regression found thyroid disease as a possible risk factor for DED (OR 4.53, 95 % CI 1.04-19.73; Fisher's exact, p = 0.044; Cramers V = 0.140, p = 0.024). No association was found between the studied parameters and Pre-clinical DED (Fisher's exact, all p ≥ 0.398; Cramers V, all p ≥ 0.242) or Predisposition to DED (Fisher's exact, all p ≥ 0.065; Cramers V, all p ≥ 0.031). CONCLUSION: Participants with thyroid disease were more likely to develop DED, therefore, thyroid disease could be a risk factor for DED.


Subject(s)
Dry Eye Syndromes , Humans , Cross-Sectional Studies , Dry Eye Syndromes/diagnosis , Dry Eye Syndromes/epidemiology , Risk Factors , Surveys and Questionnaires , Tears
11.
Ocul Immunol Inflamm ; 31(5): 970-977, 2023 Jul.
Article in English | MEDLINE | ID: mdl-35587256

ABSTRACT

OBJECTIVE: Distinguish between EDE severity levels by analysing the MGLA, conjunctival hyperemia and corneal staining. METHODS: One hundred participants were recruited based on OSDI, TO, TFBUT, TMH, and LLP to be categorised as healthy (Group 1) or EDE (Group 2). Group 2 was divided into Group 2A (mild symptoms), 2B (moderate), and 2C (severe). MGLA, conjunctival hyperemia, and corneal staining were measured. RESULTS:  Positive correlation between MGLA, conjunctival hyperemia, and corneal staining were found (all r ≥ 0.221, p ≤ 0.027). Significant differences were found: MGLA between Group 1 vs. 2C and 2C vs. 2A or 2B; conjunctival hyperemia between Group 1 vs. 2A, 2B or 2C; corneal staining between Group 1 vs. 2B or 2C and 2A vs. 2B or 2C (all p ≤ 0.049). CONCLUSION: Severe EDE participants have higher MGLA, conjunctival hyperemia, and corneal staining values than healthy, mild, or moderate EDE participants.


Subject(s)
Conjunctivitis , Dry Eye Syndromes , Hyperemia , Humans , Hyperemia/diagnosis , Tears , Dry Eye Syndromes/diagnosis
12.
Clin Exp Optom ; 106(4): 351-361, 2023 05.
Article in English | MEDLINE | ID: mdl-35410571

ABSTRACT

The measurement of tear film osmolarity has been suggested as a gold standard in the diagnosis of dry eye. Many tear film physiological variables oscillate during the day. This review summarises current clinical knowledge regarding diurnal osmolarity variation in the tear film. A critical analysis is presented in respect of of sample size and characteristics, differences in the diurnal osmolarity variation on healthy versus altered tear film conditions or environment, and time of day and number of measurements undertaken. A comparison of 21 studies was made for studies in which one of the main objectives was to analyse the variance of tear film osmolarity at different time-points in a day on human cohorts. Tear film osmolarity appeard to be somewhat influenced by the time of day in healthy subjects and patients with ocular surface disease, or altered by environmental conditions. Both healthy and non-physiological tear film cohorts showed variations in results depending on the study: no variations during the day or statistically different values at some point in the day. These differences could be in the middle of the day or between the beginning and the end of the day, with higher values in the morning than in the afternoon, or even the opposite situation. The possibility of diurnal variations in tear film osmolarity should be considered by the clinician since the time of day when the tear film measurements are made can be critical in making the right diagnosis. Future studies in the diurnal variation field may have to use a well-established range of measurement time-points and a larger group of healthy subjects and and subjects who have a tear film altered by pathological or environmental conditions.


Subject(s)
Dry Eye Syndromes , Humans , Osmolar Concentration , Dry Eye Syndromes/diagnosis , Tears/physiology
13.
Life (Basel) ; 12(12)2022 Dec 02.
Article in English | MEDLINE | ID: mdl-36556372

ABSTRACT

A decrease of the Tear Meniscus Height (TMH) has been proposed as a useful indicator for Aqueous Deficient Dry Eye (ADDE) categorization. The present study aimed to calculate a TMH cut-off criterion for the categorization or severity assessment of ADDE with the Tearscope. 200 participants with a previous Dry Eye Disease (DED) diagnosis according to TFOS DEWS-II criteria were recruited. TMH by slit-lamp illumination and Lipid Layer Pattern (LLP) with Tearscope were assessed to categorise the participants into the ADDE or the Evaporative Dry Eye (EDE) group. The ADDE group was also subdivided into Mild-moderate ADDE and Moderate-severe ADDE based on TMH with slit-lamp. Additionally, the TMH was measured by Tearscope (TMH-Tc). Receiver Operating Characteristics showed that the TMH-Tc have a diagnostic capability to differentiate between ADDE and EDE participants, and between Mild-moderate or Moderate-severe ADDE, with a cut-off value of 0.159 mm (AUC = 0.843 ± 0.035, p < 0.001; sensitivity: 86.4%; specificity: 75.4%) and 0.105 mm (AUC = 0.953 ± 0.025, p < 0.001; sensitivity: 98.1%; specificity: 80.0%), respectively. The present study proposed a cut-off criterion to differentiate between ADDE and EDE participants, or between ADDE severities through TMH assessed by Tearscope.

14.
Optom Vis Sci ; 99(2): 159-166, 2022 02 01.
Article in English | MEDLINE | ID: mdl-34897233

ABSTRACT

SIGNIFICANCE: Tear film instability has been recognized as one key mechanism on dry eye disease. There is a need for new instruments, methods, or protocols to improve the repeatability and reproducibility of the tear film stability to facilitate its clinical evaluation use as a rapid and reliable primary diagnostic test. PURPOSE: The present pilot study aimed to validate a method to automatically measure the tear film breakup time (BUT). METHODS: A total of 264 videos of BUT were randomly selected among the clinical history of subjects attending the optometry clinic. Videos were stored in a backup server through a secure file transfer protocol and analyzed by three different examiners: two masked observers (subjective evaluation) and a third investigator using the automatic software application (objective evaluation). Subjective evaluation was conducted only once on an online software designed for this protocol where videos were presented in random masked order. Automatic evaluation based on color and texture analysis was performed by (1) automatic localization of sequences of interest in the video, (2) extraction of the region of interest within each frame, and (3) automatic BUT measurement from evolution curves in the region of interest as time elapsed from the beginning of the sequence of interest until the curve exceeds a threshold. RESULTS: Substantial correlation was observed among the examiners (intraclass correlation coefficient, 0.752). There was a statistical difference between observer 1 and 2 evaluations (t test, P < .001), whereas data provided by the software showed no significant differences from those of the observers (t test, P ≥ .26). Similar results to the whole data set analysis were obtained when the sample was reassessed only considering mean BUT values ≤15 seconds. CONCLUSIONS: The present pilot study showed acceptable clinical results for the software application designed to objectively measure the BUT.


Subject(s)
Dry Eye Syndromes , Tears , Dry Eye Syndromes/diagnosis , Humans , Pilot Projects , Reproducibility of Results , Software
15.
Clin Exp Optom ; 104(6): 691-697, 2021 08.
Article in English | MEDLINE | ID: mdl-33689665

ABSTRACT

CLINICAL RELEVANCE: Variation with time in the tear film parameters should be considered by the clinician since the time when measurements are made can influence proper diagnosis. BACKGROUND: A hallmark of dry eye is an unstable tear film associated with variability in objective daily measures. The purpose of the present study was to evaluate the inter-week repeatability of meibometry, break-up time (BUT) and maximum blink interval (MBI) in healthy subjects. METHODS: Forty healthy subjects were recruited for the study. Meibometry, BUT and MBI were performed twice in two sessions, one-week apart. Meibum from the lower eyelid was collected and quantified with the Meibometer MB550. Five meibomian curves were generated by tape and each peak value was averaged as a mean value per session. BUT and MBI were determined three times after fluorescein instillation and recorded by a DV-3 camera attached to the slit lamp. BUT and MBI videos were analysed by a second masked observer. Both BUT and MBI values were calculated by averaging the two most similar measurements of the three evaluated. RESULTS: No statistical difference between inter-week sessions was obtained for the meibometry (p > 0.340; Wilcoxon test), BUT (p > 0.326; Wilcoxon test) and MBI values (p ≥ 0.248; Wilcoxon test). Inter-week differences were low for BUT and MBI when time intervals were no longer than 15 seconds (both p ≥ 0.586; Wilcoxon test). A correlation between BUT and MBI was found (r ≥ 0.668, p < 0.001; Spearman Rho), while a no statistical correlation was obtained between meibometry results and BUT or MBI (all p ≥ 0.194; Spearman Rho). CONCLUSION: Meibum secretion and the tear film stability present good intersession repeatability, and are stable along with sessions in healthy patients.


Subject(s)
Dry Eye Syndromes , Tears , Blinking , Dry Eye Syndromes/diagnosis , Fluorescein , Healthy Volunteers , Humans
16.
Cont Lens Anterior Eye ; 44(4): 101379, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33187860

ABSTRACT

PURPOSE: The physical properties of contact lens care solutions and Eye Drops (ED) may affect initial comfort and dry eye symptomatology in contact lens wearers, although these properties are not always provided by manufacturers. The present study aimed to measure and compare the osmolality and pH of commercially available contact lens care solutions and ED. METHODS: Forty-four solutions were tested (17 lens care solutions and 27 ED) and classified by the presence and/or combination of the viscosity/lubrication-enhancing ingredients. Solution osmolality was obtained with the Fiske 110 osmometer and pH was measured with a micro-pH 2000. Each measurement was taken ten times, following the manufacturer's instructions, while controlling for room temperature and humidity. Differences between the values of the physical properties of the solutions were analysed by type and viscosity/lubrication-enhancing agent subclassification. RESULTS: Osmolality ranged from 192.6 ± 2.17 to 364.6 ± 2.88 mOsm/Kg, while pH ranged from 6.35 [6.35-6.26] to 7.99 [7.99-8.00]. A significant difference in the osmolality and pH values of contact lens care solutions and ED was found when classified by type or viscosity/lubrication-enhancing agent (ANOVA and Kruskal-Wallis respectively, both p < 0.001). CONCLUSIONS: The physical properties of some contact lens care solutions and ED are not readily available. The osmolality and pH values of various commercially available lens care solutions and ED vary significantly both by type and viscosity/lubrication-enhancing ingredients.


Subject(s)
Contact Lens Solutions , Contact Lenses , Humans , Hydrogen-Ion Concentration , Ophthalmic Solutions , Osmolar Concentration
17.
Arq. bras. oftalmol ; 83(2): 103-108, Mar.-Apr. 2020. tab, graf
Article in English | LILACS | ID: biblio-1088971

ABSTRACT

ABSTRACT Purpose: To analyze whether inter-eye osmo larity differences were related to dry eye symptomatology. Methods: A total of 135 participants were randomly recruited from those who visited in the Optometry Clinic of the Optometry Faculty (Universidade de Santiago de Compostela). In a single scheduled session after the recruitment, Ocular Surface Disease Index was filled out following the standard instructions and TearLab measurements were made in both the participants' eyes (10-15 min lapse). Osmolarity values were compared between the right and left eyes and the absolute inter-ocular difference (-OD-OS-) correlated with the Ocular Surface Disease Index score for the whole sample. Based on the Ocular Surface Disease Index score, the sample was divided into four symptomatic subgroups, and differences in the -OD-OS- values were calculated. Results: The whole sample showed a statistically significant inter-eye osmolarity difference (p=0.025; -OD-OS- = 9.2 ± 9.3 mOsm/l) and the correlation between Ocular Surface Disease Index and -OD-OS- (r=0.369; p<0.001). A statistically significant difference was found in the -OD-OS- value between symptomatic subgroups (Kruskal-Wallis, p=0.003). Mann-Whitney U test showed a significant difference between asymptomatic vs. moderate (p=0.006) vs. severe symp tomatic patients (p=0.001) and between mild vs. severe symptomatic patients (p=0.045), whereas no difference on -OD-OS- was found between participants with contiguous symptomatic subgroups (all p³0.174). Conclusion: Tear film inter-eye osmolarity differences are significantly higher in severe dry eye disease symptoms.


RESUMO Objetivo: Analisar se as diferenças entre osmolaridade entre os olhos foram relacionadas à sintomatologia do olho seco. Métodos: Um total de 135 participantes foram recrutados aleatoriamente entre os indivíduos da Clínica de Optometria da Faculdade de Optometria (Universidade de Santiago de Compostela). Em uma única sessão agendada após o recrutamento, o Índice de Doenças da Superfície Ocular foi preenchido seguindo as instruções padrão e as mensurações do TearLab foram feitas em ambos os olhos dos participantes (lapso de 10 a 15 min). Os valores de osmolaridade foram com parados entre os olhos direito e o esquerdo e a diferença absoluta ocular (-OD-OS-) correlacionada com a pontuação do Índice de Doença da Superfície Ocular para toda a amostra. Com base na pontuação do Índice de Doença da Superfície Ocular, a amostra foi dividida em quatro subgrupos sintomáticos, e as diferenças nos -OD-OS- os valores foram calcula dos. Resultados: A amostra total mostrou uma diferença de osmolarida de entre os olhos estatisticamente significativa (p=0,025; -OD-OS- = 9,2 ± 9,3 mOsm/l) e a correlação entre o Índice de Doença da Superfície Ocular e -OD-OS- (r=0,369; p<0,001). Diferença estatisticamente significativa foi encontrada no valor -OD-OS- entre os subgrupos sintomáticos (Kruskal-Wallis, p=0,003). O teste U de Mann-Whitney mostrou uma diferença significativa entre pacientes assintomáticos versus moderados (p=0,006) versus sintomáticos graves (p=0,001) e entre pacientes sinto máticos leves e graves (p=0,045), enquanto que nenhuma di ferença de -OD-OS- foi encontrada entre os participantes de subgrupos sintomáticos contíguos (todos p³0,174). Conclusão: As diferenças entre osmolaridade inter-ocular do filme lacrimal são significativamente maiores nos sintomas graves da doença do olho seco.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Young Adult , Tears/chemistry , Dry Eye Syndromes/physiopathology , Osmolar Concentration , Reference Values , Severity of Illness Index , Surveys and Questionnaires , Statistics, Nonparametric
18.
Arq Bras Oftalmol ; 83(2): 103-108, 2020.
Article in English | MEDLINE | ID: mdl-32159592

ABSTRACT

PURPOSE: To analyze whether inter-eye osmo larity differences were related to dry eye symptomatology. METHODS: A total of 135 participants were randomly recruited from those who visited in the Optometry Clinic of the Optometry Faculty (Universidade de Santiago de Compostela). In a single scheduled session after the recruitment, Ocular Surface Disease Index was filled out following the standard instructions and TearLab measurements were made in both the participants' eyes (10-15 min lapse). Osmolarity values were compared between the right and left eyes and the absolute inter-ocular difference (|OD-OS|) correlated with the Ocular Surface Disease Index score for the whole sample. Based on the Ocular Surface Disease Index score, the sample was divided into four symptomatic subgroups, and differences in the |OD-OS| values were calculated. RESULTS: The whole sample showed a statistically significant inter-eye osmolarity difference (p=0.025; |OD-OS| = 9.2 ± 9.3 mOsm/l) and the correlation between Ocular Surface Disease Index and |OD-OS| (r=0.369; p<0.001). A statistically significant difference was found in the |OD-OS| value between symptomatic subgroups (Kruskal-Wallis, p=0.003). Mann-Whitney U test showed a significant difference between asymptomatic vs. moderate (p=0.006) vs. severe symp tomatic patients (p=0.001) and between mild vs. severe symptomatic patients (p=0.045), whereas no difference on |OD-OS| was found between participants with contiguous symptomatic subgroups (all p³0.174). CONCLUSION: Tear film inter-eye osmolarity differences are significantly higher in severe dry eye disease symptoms.


Subject(s)
Dry Eye Syndromes/physiopathology , Tears/chemistry , Adult , Aged , Female , Humans , Male , Middle Aged , Osmolar Concentration , Reference Values , Severity of Illness Index , Statistics, Nonparametric , Surveys and Questionnaires , Young Adult
19.
Clin Exp Optom ; 102(6): 571-575, 2019 11.
Article in English | MEDLINE | ID: mdl-30818419

ABSTRACT

BACKGROUND: Hyperosmolarity of tear fluid has been recognised as a common feature of all types of dry eye disease. This study was designed to assess the inter-session reproducibility of a freezing point depression osmometer (Fiske 110) as the most common and precise way of measuring osmolality, by using two different volumes of tear samples on healthy subjects, and to determine the possible applications of this device in tear film research and clinical practice. METHODS: Measurements were made by using the Fiske 110 osmometer under two different tear sample volumes (4 µl and 2 µl). In both cases, samples were diluted in purified water to obtain the 20 µl required by the device to perform the measurement (1:4 and 1:9 dilutions, respectively). Inter-session reproducibility was determined in two groups of 40 healthy subjects, in two sessions, one week apart. In each group, one of the two different tear sample volumes was used to determine the reproducibility of each technique. RESULTS: No significant differences were detected between the measurements obtained in the two sessions using the 4 µl (paired t-test, p = 0.772; mean difference ± SD = -0.85 ± 18.77 mOsm/L; 95 per cent limits of agreement [LoAs] = -37.64/+35.94) or the 2 µl volume sample (paired t-test, p = 0.054; mean difference ± SD = 9.27 ± 29.44 mOsm/L; 95 per cent LoAs = -48.43/+66.97). CONCLUSIONS: Whereas both techniques show an acceptable inter-session reproducibility, the bias range with the present protocol was higher using the 2 µl tear sample volume than the 4 µl one. Therefore, it seems that the diluted 4 µl sample was the only dilution that could be acceptable for use in routine clinical practice for tear film analysis.


Subject(s)
Tears/chemistry , Dry Eye Syndromes/metabolism , Freezing , Humans , Osmolar Concentration , Reproducibility of Results , Specimen Handling
SELECTION OF CITATIONS
SEARCH DETAIL
...